The Approximate Full Load Amperage (FLA) for a Single-Phase, 2 HP Motor Operating on 230 V

Explanation:

The question asks about the approximate Full Load Amperage (FLA) for a single-phase, 2 HP motor operating at 230 V. Typically, to estimate the FLA of a motor, you can use the power formula P = IV, where P is the power in watts, I is the current in amperes, and V is the voltage. For a 2 HP motor, and knowing that 1 horsepower is equivalent to 746 watts, we calculate the motor power as P = 2 HP × 746 W/HP = 1492 W. Using the given voltage, V = 230 V, we can solve for the current I using the formula I = P/V,thus obtaining I ≈ 1492 W / 230 V ≈ 6.49 A. Therefore, the approximate FLA for the motor is 6.49 A.

← Understanding one time use hardware the case of rivets To which of the following is it illegal to attach your vessel →